Max allowed cornering g-force (1/100 g). Set to zero to disable
Voltage (1/10 V) above which engine is running. Set to zero to disable. When
disabled, unit will use Engine On input or IGN to assume engine running. This
setting is used to count engine hours and calculate drive and idle times.
Accelerometer rotation around X axis (radians*10000). Set to zero to
recalibrate
Accelerometer rotation around Y axis (radians*10000). Set to zero to
recalibrate
Max allowed tilt when stationary (degrees). Set to zero to disable
Set g-force required to trigger motion detection (approx 1/1000 g). Range 1-255
UDP port for sending and receiving transparent data during a dial-up or Wi-Fi
connection. Set to zero to disable
UDP port for sending and receiving message/email data during a dial-up or Wi-
Fi connection. Set to zero to disable
Engine Hours (1/100 gallons)
Advanced GPS report. Bit 2=Digital I/O States. Bit 3=Cell Info. Bit 4=ADC2. Bit
5=ADC1. Bit 6=Battery Voltage. Bit 7=Temperature. Bit 8=Speed. Bit
9=Altitude. Bit 10=Heading. Bit 11=GPS HDOP
Bit 1=Send NTCIP data in UDP format. Bit 0=Enable transparent access to sign
terminal
NTCIP Sign Message Number. Set to zero to use AMSIG protocol
Kenwood settings. Bit 7=Long data. Bit 6=NXDN. Bit 5=Software ACKs. Bit
4=WAN mode. Bit 3=Transparent. Bit 0=KW Prot Ver 1
RF COM settings. Bits 0-1=(Data bits-5). Bit 2=Extra Stop bits. Bit 3=Parity. Bit
4=Even
Kenwood unit number used as destination when sending data (0000, 1000-
4999 for Fleetsync, or 00000-65519 for NXDN)
Kenwood fleet/ID type for sending data (0, 100-349 for Fleetsync, or 0=GID,
1=UID, 2=Broadcast for NXDN)
Engine volumetric efficiency (%)
Low battery warning (1/10 V). Set to zero to disable
Output 4 Setting. See note at bottom for values
Output 4 polarity (0=Low 1=High)
VOUT function. See I/O note at bottom for values
VOUT polarity (0=Low 1=High)
Trigger event if ADC1 exceeds this voltage (1/10 V). Set to zero to disable
Trigger event if ADC1 drops under this voltage (1/10 V). Set to zero to disable
Trigger event if ADC2 exceeds this voltage (1/10 V). Set to zero to disable
Trigger event if ADC2 drops under this voltage (1/10 V). Set to zero to disable
Debounce time (ms) for ADC1 changes
Debounce time (ms) for ADC2 changes
Send alert if GPS signal is unavailable for this period (sec). Ver 4.88 and later
only increment this counter while vehicle is moving.
Kenwood unit number used to listen for data from base radio (1000-4999 for
Fleetsync, or 00001-65519 for NXDN). Set to zero to use I_UNIT
Kenwood fleet ID used to listen for data from base radio (Fleetsync only). Set to
zero to use I_FLEET