7.3 Device Info
Device information is displayed in the Info frame. Any errors or important values will be shown in red.
7.3.1 Status
PC Connected To: i50 port being used for programming.
Settings: Status of settings inside i50.
Clock: Clock status. Use the Set button to adjust the i50 clock to match the PC.
Time: Value of real-time clock (RTC) inside i50. If the clock does not maintain its
setting after power is removed from the unit for more than 10 seconds, the
internal backup battery may need replacing.
VOUT: Status of VOUT driver.
ADC: Status of internal analog to digital converter (ADC).
Accel: Status of internal 3D accelerometer.
Buffer: Shows how many events or positions are currently stored in memory. This
buffer can be cleared using the Clear Buffer command, or read and saved
to disk using the Get Buffer command. When packets are present this
value will be shown in red, to remind the user that there may be useful
data in memory.
7.3.2 Inputs
IGN: IGN input (Off/On)
IN1: IN1 (Low/High)
IN2: IN2 (Low/High)
IN3: IN3 (Low/High)
IN4: IN4 (Low/High)
ADC1: Voltage on ADC1 pin
ADC2: Voltage on ADC2 pin
7.3.3 Other
Battery: Voltage on PWR pin
Temp: Internal temperature
G-Force: Current g-force readings in X, Y, and Z planes. The X plane relates to
cornering forces; the Y plane to acceleration and braking forces; and Z to
up/down forces.